Generally, the
Huawei ME60/Huawei NE40E sets an Ethernet interface to an optical or electrical interface
based on the interface module's type. If the NE80E/40E cannot identify an
interface module, you need to manually set the interface to the optical or
electrical mode.
Run:
system-view
The system view is
displayed.
Run:
interface { ethernet
| gigabitethernet } interface-number
The Ethernet
interface view is displayed.
Run:
port-type { copper |
fiber-100 | fiber-1000 }
The interface type
is set.
Once the SFP module
is identified, the system can automatically set the interface type according to
the type of the SFP module. No configuration is required.
If the SFP module
that cannot be identified works well, you need to forcibly set the interface
type.
NOTE:
When an SFP module
is being replaced, the configurations such as the loopback test, interface
speed, auto-negotiation mode, and duplex mode on the interface are all restored
to default ones. You need to reconfigure them on the interface.
After the port-type
command is run, the configurations such as the loopback test, interface speed,
auto-negotiation mode, and duplex mode on the interface are all restored to
default ones. You need to reconfigure them on the interface.
The parameter copper
can be configured in the port-type command only when an optical/electrical SFP
module is installed.